Inductive power transfer system with self-calibrated primary resonant frequency A Trigui, S Hached, F Mounaim, AC Ammari, M Sawan IEEE Transactions on power electronics 30 (11), 6078-6087, 2015 | 80 | 2015 |
Maximizing data transmission rate for implantable devices over a single inductive link: Methodological review A Trigui, S Hached, AC Ammari, Y Savaria, M Sawan IEEE reviews in biomedical engineering 12, 72-87, 2018 | 55 | 2018 |
Generic wireless power transfer and data communication system based on a novel modulation technique A Trigui, M Ali, S Hached, JP David, AC Ammari, Y Savaria, M Sawan IEEE Transactions on Circuits and Systems I: Regular Papers 67 (11), 3978-3990, 2020 | 35 | 2020 |
A Bluetooth-based Low-Energy Qi-compliant battery charger for implantable medical devices S Hached, A Trigui, I El Khalloufi, M Sawan, O Loutochin, J Corcos 2014 IEEE International Symposium on Bioelectronics and Bioinformatics (IEEE …, 2014 | 26 | 2014 |
Novel, wirelessly controlled, and adaptive artificial urinary sphincter S Hached, Z Saadaoui, O Loutochin, A Garon, J Corcos, M Sawan IEEE/ASME Transactions on Mechatronics 20 (6), 3040-3052, 2015 | 21 | 2015 |
Novel, remotely controlled, artificial urinary sphincter: a retro-compatible device S Hached, O Loutochin, J Corcos, A Garon, M Sawan IEEE/ASME Transactions on Mechatronics 19 (4), 1352-1362, 2013 | 20 | 2013 |
Montreal electronic artificial urinary sphincters: Our futuristic alternatives to the AMS800™ X Biardeau, S Hached, O Loutochin, L Campeau, M Sawan, J Corcos Canadian Urological Association Journal 11 (10), E396, 2017 | 19 | 2017 |
Implantable MICS-based wireless solution for bladder pressure monitoring A Tantin, A Letourneau, M Zgaren, S Hached, I Clausen, M Sawan 2017 IEEE Biomedical Circuits and Systems Conference (BioCAS), 1-4, 2017 | 15 | 2017 |
Stability of GaN150-based HEMT in high temperature up to 400° C A Hassan, M Ali, A Trigui, S Hached, Y Savaria, M Sawan 2017 15th IEEE International New Circuits and Systems Conference (NEWCAS …, 2017 | 12 | 2017 |
Predicting urinary bladder voiding by means of a linear discriminant analysis: validation in rats A Tantin, EB Assi, E Van Asselt, S Hached, M Sawan Biomedical Signal Processing and Control 55, 101667, 2020 | 10 | 2020 |
Novel electromechanic artificial urinary sphincter S Hached, A Trigui, O Loutochin, A Garon, J Corcos, M Sawan IEEE/ASME Transactions on Mechatronics 21 (2), 945-955, 2015 | 9 | 2015 |
1375 novel, remotely-controlled, artificial urinary sphincter: a retro-compatible device J Corcos, S Hached, O Loutochin, M Sawan The Journal of Urology 189 (4S), e562-e562, 2013 | 8 | 2013 |
Development of a novel remotely-controlled artificial urinary sphincter: a retro-compatible device J Corcos, S Hached, O Loutochin, M Sawan Neurourology and Urodynamics 32 (2), 128-129, 2013 | 2 | 2013 |
Smart artificial urinary sphincters: implementation challenges S Hached, A Garon, M Sawan, O Loutochin, J Corcos 2016 IEEE 59th International Midwest Symposium on Circuits and Systems …, 2016 | 1 | 2016 |
Automatic control of inductive energy transmitted to electronic implants A Trigui, S Hached, M Sawan | 1 | 2013 |
Sphincter urinaire artificiel électromécanique: résultats in vitro X Biardeau, S Hached, O Lotouchin, L Campeau, M Sawan, J Corcos Progrès en Urologie 25 (13), 842, 2015 | | 2015 |
Sphincter artificiel contrôlé et alimenté en énergie sans fil S Hached École Polytechnique de Montréal, 2015 | | 2015 |
Sphincter urinaire artificiel intelligent: préserver organes et qualité de vie du patient S Hached, A Garon, M Sawan, O Loutochin, J Corcos | | 2014 |
Sphincter artificiel électronique télé-commandé et compatible avec le sphincter AMS 800 R Caremel, J Corcos, S Hached, O Lotouchin, M Sawan Progrès en Urologie 23 (13), 1071, 2013 | | 2013 |
A Novel Remotely controlled artificial urinary sphincter S Hached, O Loutochin, J Corcos, M Sawan | | 2013 |