Koen Michielsen
Koen Michielsen
Radboudumc
Verified email at radboudumc.nl
Title
Cited by
Cited by
Year
Development and applicability of a quality control phantom for dental cone-beam CT
R Pauwels, H Stamatakis, G Manousaridis, A Walker, K Michielsen, ...
Journal of Applied Clinical Medical Physics 12 (4), 245-260, 2011
882011
Image quality assessment and medical physics evaluation of different portable dental X-ray units
P Pittayapat, C Oliveira-Santos, P Thevissen, K Michielsen, N Bergans, ...
Forensic Science International 201 (1-3), 112-117, 2010
412010
Design and application of a structured phantom for detection performance comparison between breast tomosynthesis and digital mammography
L Cockmartin, NW Marshall, G Zhang, K Lemmens, E Shaheen, ...
Physics in Medicine & Biology 62 (3), 758, 2017
402017
Results of a European dose survey for mammography
K Michielsen, J Jacobs, K Lemmens, J Nens, J Zoetelief, K Faulkner, ...
Radiation Protection Dosimetry 129 (1-3), 199-203, 2008
212008
Patchwork reconstruction with resolution modeling for digital breast tomosynthesis
K Michielsen, K Van Slambrouck, A Jerebko, J Nuyts
Medical Physics 40 (3), 031105, 2013
172013
The relationship between the attenuation properties of breast microcalcifications and aluminum
F Zanca, C Van Ongeval, N Marshall, T Meylaers, K Michielsen, ...
Physics in Medicine and Biology 55 (4), 1057, 2010
132010
Design of a model observer to evaluate calcification detectability in breast tomosynthesis and application to smoothing prior optimization
K Michielsen, J Nuyts, L Cockmartin, N Marshall, H Bosmans
Medical Physics 43 (12), 6577-6587, 2016
112016
2D versus 3D roadmap for uterine artery catheterization: impact on several angiographic parameters
G Maleux, K Michielsen, D Timmerman, W Poppe, S Heye, J Vaninbroukx, ...
Acta Radiologica 55 (1), 62-70, 2014
112014
One year of experience with remote quality assurance of digital mammography systems in the Flemish breast cancer screening program
J Jacobs, K Lemmens, J Nens, K Michielsen, G Marchal, H Bosmans
International Workshop on Digital Mammography, 703-710, 2008
112008
Image quality comparison between a phase-contrast synchrotron radiation breast CT and a clinical breast CT: a phantom based study
L Brombal, F Arfelli, P Delogu, S Donato, G Mettivier, K Michielsen, ...
Scientific reports 9 (1), 1-12, 2019
102019
Multi-phase rotational angiography of the left ventricle to assist ablations: feasibility and accuracy of novel imaging
JY Wielandts, S De Buck, K Michielsen, R Louw, C Garweg, J Nuyts, ...
European Heart Journal-Cardiovascular Imaging 17 (2), 162-168, 2016
92016
Impact of compressed breast thickness and dose on lesion detectability in digital mammography: FROC study with simulated lesions in real mammograms
E Salvagnini, H Bosmans, C Van Ongeval, A Van Steen, K Michielsen, ...
Medical Physics 43 (9), 5104-5116, 2016
72016
Plane-by-plane iterative reconstruction for digital breast tomosynthesis
A Jerebko, K Michielsen, J Nuyts
US Patent 8,594,407, 2013
72013
Deep learning framework for digital breast tomosynthesis reconstruction
N Moriakov, K Michielsen, J Adler, R Mann, I Sechopoulos, J Teuwen
Medical Imaging 2019: Physics of Medical Imaging 10948, 1094804, 2019
62019
Multigrid Reconstruction with Block-Iterative Updates for Breast Tomosynthesis
K Michielsen, J Nuyts
Medical Physics 42 (11), 2015
62015
Development and application of a channelized Hotelling observer for DBT optimization on structured background test images with mass simulating targets
D Petrov, K Michielsen, L Cockmartin, G Zhang, K Young, N Marshall, ...
Medical Imaging 2016: Image Perception, Observer Performance, and Technology …, 2016
52016
Artifact reduction in breast tomosynthesis by including prior knowledge of the compressed breast shape
K Michielsen, A Rodríguez-Ruiz, G Agasthya, I Sechopoulos
Proc. Intl. Mtg. on Fully 3D Image Recon. in Rad. and Nuc. Med, 186-190, 2017
42017
Contrast-detail comparison between unprocessed and processed CDMAM images
F Zanca, H Bosmans, J Jacobs, K Michielsen, F Sisini, J Nens, KC Young, ...
SPIE Medical Imaging: Physics of Medical Imaging 7258, 2009
42009
Deep learning reconstruction of digital breast tomosynthesis images for accurate breast density and patient-specific radiation dose estimation
J Teuwen, N Moriakov, C Fedon, M Caballo, I Reiser, P Bakic, E García, ...
Medical Image Analysis, 102061, 2021
32021
Two complementary model observers to evaluate reconstructions of simulated micro-calcifications in digital breast tomosynthesis
K Michielsen, F Zanca, N Marshall, H Bosmans, J Nuyts
SPIE Medical Imaging: Image Perception, 86730G, 2013
32013
The system can't perform the operation now. Try again later.