Angel Molina-Garcia (orcid.org/0000-0001-6824-8684)
Angel Molina-Garcia (orcid.org/0000-0001-6824-8684)
Universidad Politecnica de Cartagena (Spain) - grid.218430.c - https://ror.org/02k5kx966
Verified email at upct.es - Homepage
Title
Cited by
Cited by
Year
Decentralized demand-side contribution to primary frequency control
A Molina-Garcia, F Bouffard, DS Kirschen
IEEE Transactions on Power Systems 26 (1), 411-419, 2011
4842011
Implementation and assessment of physically based electrical load models: application to direct load control residential programmes
A Molina, A Gabaldon, JA Fuentes, C Alvarez
IEE Proceedings-Generation, Transmission and Distribution 150 (1), 61-66, 2003
1312003
Assessment and simulation of the responsive demand potential in end-user facilities: application to a university customer
C Alvarez, A Gabaldón, A Molina
IEEE Transactions on Power Systems 19 (2), 1223-1231, 2004
1022004
Probabilistic characterization of thermostatically controlled loads to model the impact of demand response programs
A Molina-Garcia, M Kessler, JA Fuentes, E Gomez-Lazaro
IEEE Transactions on power systems 26 (1), 241-251, 2011
942011
Reactive power flow control for PV inverters voltage support in LV distribution networks
Á Molina-García, RA Mastromauro, T García-Sánchez, S Pugliese, ...
IEEE Transactions on Smart Grid 8 (1), 447-456, 2017
872017
Influence of voltage dips on industrial equipment: Analysis and assessment
A Honrubia-Escribano, E Gómez-Lázaro, A Molina-Garcia, JA Fuentes
International Journal of Electrical Power & Energy Systems 41 (1), 87-95, 2012
852012
Demand-side contribution to primary frequency control with wind farm auxiliary control
A Molina-García, I Munoz-Benavente, AD Hansen, E Gómez-Lázaro
IEEE Transactions on Power Systems 29 (5), 2391-2399, 2014
692014
Characterization and identification of electrical customers through the use of self-organizing maps and daily load parameters
SV Verdu, MO García, FJG Franco, N Encinas, AG Marin, A Molina, ...
IEEE PES Power Systems Conference and Exposition, 2004., 899-906, 2004
572004
Power quality surveys of photovoltaic power plants: characterisation and analysis of grid-code requirements
A Honrubia-Escribano, T García-Sánchez, E Gómez-Lázaro, E Muljadi, ...
IET Renewable Power Generation 9 (5), 466-473, 2015
542015
Power systems with high renewable energy sources: A review of inertia and frequency control strategies over time
A Fernández-Guillamón, E Gómez-Lázaro, E Muljadi, Á Molina-García
Renewable and Sustainable Energy Reviews 115, 109369, 2019
442019
Assessment and simulation of demand-side management potential in urban power distribution networks
A Gabaldon, A Molina, C Roldan, JA Fuentes, E Gomez, ...
2003 IEEE Bologna Power Tech Conference Proceedings, 4, 5 pp. Vol. 4, 2003
342003
Characterization and visualization of voltage dips in wind power installations
E Gómez-Lázaro, JA Fuentes, A Molina-García, M Cañas-Carretón
IEEE Transactions on Power Delivery 24 (4), 2071-2078, 2009
332009
An integrated tool for assessing the demand profile flexibility
JAF Moreno, AM García, AG Marín, EG Lázaro, CA Bel
IEEE Transactions on Power Systems 19 (1), 668-675, 2004
322004
Impact of wind power curtailments on the Spanish power system operation
S Martín-Martínez, E Gómez-Lazaro, A Molina-Garcia, ...
2014 IEEE PES General Meeting| Conference & Exposition, 1-5, 2014
302014
Field tests of wind turbines submitted to real voltage dips under the new spanish grid code requirements
E Gómez, JA Fuentes, A Molina‐García, F Ruz, F Jiménez
Wind Energy: An International Journal for Progress and Applications in Wind …, 2007
302007
Approach to multivariable predictive control applications in residential HVAC direct load control
A Molina, A Gabaldon, JA Fuentes, FJ Canovas
2000 Power Engineering Society Summer Meeting (Cat. No. 00CH37134) 3, 1811-1816, 2000
292000
Validation of a DFIG wind turbine model submitted to two-phase voltage dips following the Spanish grid code
F Jiménez, E Gómez-Lázaro, JA Fuentes, A Molina-García, ...
Renewable energy 57, 27-34, 2013
282013
Validation of a double fed induction generator wind turbine model and wind farm verification following the Spanish grid code
F Jiménez, E Gómez‐Lázaro, JA Fuentes, A Molina‐García, ...
Wind Energy 15 (4), 645-659, 2012
282012
Load influence on the response of AC-Contactors under power quality disturbances
A Honrubia-Escribano, E Gómez-Lázaro, A Molina-Garcia, ...
International Journal of Electrical Power & Energy Systems 63, 846-854, 2014
222014
Wind turbine modeling: Comparison of advanced tools for transient analysis
JA Fuentes, A Molina, F Ruz, E Gómez, F Jiménez
2007 IEEE Power Engineering Society General Meeting, 1-6, 2007
222007
The system can't perform the operation now. Try again later.
Articles 1–20