Charge collection and absorption-limited sensitivity of x-ray photoconductors: Applications to and MZ Kabir, SO Kasap
Applied Physics Letters 80 (9), 1664-1666, 2002
119 2002 Recent advances in X-ray photoconductors for direct conversion X-ray image detectors SO Kasap, MZ Kabir, JA Rowlands
Current Applied Physics 6 (3), 288-292, 2006
117 2006 Effects of charge carrier trapping on polycrystalline PbO X-ray imaging detectors MZ Kabir
Journal of applied physics 104 (7), 2008
74 2008 Dark current in multilayer amorphous selenium x-ray imaging detectors SA Mahmood, MZ Kabir, O Tousignant, H Mani, J Greenspan, P Botka
Applied Physics Letters 92 (22), 2008
63 2008 Photoconductors for x-ray image detectors MZ Kabir, S Kasap
Springer handbook of electronic and photonic materials, 1-1, 2017
56 * 2017 Recombination of drifting holes with trapped electrons in stabilized a -Se photoconductors: Langevin recombination SO Kasap, B Fogal, M Zahangir Kabir, RE Johanson, SK O’Leary
Applied physics letters 84 (11), 1991-1993, 2004
50 2004 An analytical model for analyzing the current-voltage characteristics of bulk heterojunction organic solar cells SM Arnab, MZ Kabir
Journal of applied physics 115 (3), 2014
47 2014 Evaluation of organic perovskite photoconductors for direct conversion X-ray imaging detectors DM Panneerselvam, MZ Kabir
Journal of Materials Science: Materials in Electronics 28, 7083-7090, 2017
46 2017 Modulation transfer function of photoconductive x-ray image detectors: effects of charge carrier trapping MZ Kabir, SO Kasap
Journal of Physics D: Applied Physics 36 (19), 2352, 2003
43 2003 Dark current mechanisms in stabilized amorphous selenium based ni detectors for x-ray imaging applications SA Mahmood, MZ Kabir
Journal of Vacuum Science & Technology A 29 (3), 2011
42 2011 DQE of photoconductive x-ray image detectors: application to a-Se MZ Kabir, SO Kasap
Journal of Physics D: Applied Physics 35 (21), 2735, 2002
41 2002 Sensitivity of stabilized a-Se based X-ray photoconductors MZ Kabir, M Yunus, SO Kasap, O Tousignant, H Mani, P Gauthier
Current Applied Physics 6 (3), 393-398, 2006
37 2006 Sensitivity of x-ray photoconductors: Charge trapping and absorption-limited universal sensitivity curves M Zahangir Kabir, SO Kasap
Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films 20 (3 …, 2002
37 2002 The effects of large signals on charge collection in radiation detectors: Application to amorphous selenium detectors MZ Kabir, EV Emelianova, VI Arkhipov, M Yunus, SO Kasap, ...
Journal of applied physics 99 (12), 2006
36 2006 Direct conversion x-ray sensors: Sensitivity, DQE and MTF MZ Kabir, SO Kasap, W Zhao, JA Rowlands
IEE Proceedings-Circuits, Devices and Systems 150 (4), 258-266, 2003
36 2003 Effect of repeated x‐ray exposure on the resolution of amorphous selenium based x‐ray imagers MZ Kabir, L Chowdhury, G DeCrescenzo, O Tousignant, SO Kasap, ...
Medical physics 37 (3), 1339-1349, 2010
34 2010 Charge collection efficiency in the presence of non-uniform carrier drift mobilities and lifetimes in photoconductive detectors SO Kasap, MZ Kabir, KO Ramaswami, RE Johanson, RJ Curry
Journal of Applied Physics 128 (12), 2020
29 2020 Dark current mechanisms in amorphous selenium-based photoconductive detectors: an overview and re-examination MZ Kabir
Journal of Materials Science: Materials in Electronics 26, 4659-4667, 2015
29 2015 Modeling of current–voltage characteristics of thin film solar cells MA Mannan, MS Anjan, MZ Kabir
Solid-state electronics 63 (1), 49-54, 2011
29 2011 Time and exposure dependent x-ray sensitivity in multilayer amorphous selenium detectors F Manouchehri, MZ Kabir, O Tousignant, H Mani, VK Devabhaktuni
Journal of Physics D: Applied Physics 41 (23), 235106, 2008
27 2008