Seuraa
Stuart Cogan
Stuart Cogan
Vahvistettu sähköpostiosoite verkkotunnuksessa utdallas.edu - Kotisivu
Nimike
Viittaukset
Viittaukset
Vuosi
Neural stimulation and recording electrodes
SF Cogan
Annu. Rev. Biomed. Eng. 10 (1), 275-309, 2008
25572008
Tissue damage thresholds during therapeutic electrical stimulation
SF Cogan, KA Ludwig, CG Welle, P Takmakov
Journal of neural engineering 13 (2), 021001, 2016
3712016
Electrodeposited iridium oxide for neural stimulation and recording electrodes
RD Meyer, SF Cogan, TH Nguyen, RD Rauh
IEEE Transactions on Neural Systems and Rehabilitation Engineering 9 (1), 2-11, 2001
3432001
Optical properties of electrochromic vanadium pentoxide
SF Cogan, NM Nguyen, SJ Perrotti, RD Rauh
Journal of applied physics 66 (3), 1333-1337, 1989
2581989
Over-pulsing degrades activated iridium oxide films used for intracortical neural stimulation
SF Cogan, AA Guzelian, WF Agnew, TGH Yuen, DB McCreery
Journal of neuroscience methods 137 (2), 141-150, 2004
2522004
In vitro comparison of the charge-injection limits of activated iridium oxide (AIROF) and platinum-iridium microelectrodes
SF Cogan, PR Troyk, J Ehrlich, TD Plante
IEEE Transactions on Biomedical Engineering 52 (9), 1612-1614, 2005
2182005
Sputtered iridium oxide films for neural stimulation electrodes
SF Cogan, J Ehrlich, TD Plante, A Smirnov, DB Shire, M Gingerich, ...
Journal of Biomedical Materials Research Part B: Applied Biomaterials: An …, 2009
2162009
A model for intracortical visual prosthesis research
P Troyk, M Bak, J Berg, D Bradley, S Cogan, R Erickson, C Kufta, ...
Artificial organs 27 (11), 1005-1015, 2003
2162003
Plasma‐enhanced chemical vapor deposited silicon carbide as an implantable dielectric coating
SF Cogan, DJ Edell, AA Guzelian, Y Ping Liu, R Edell
Journal of Biomedical Materials Research Part A: An Official Journal of The …, 2003
2092003
Development and implantation of a minimally invasive wireless subretinal neurostimulator
DB Shire, SK Kelly, J Chen, P Doyle, MD Gingerich, SF Cogan, ...
IEEE Transactions on Biomedical Engineering 56 (10), 2502-2511, 2009
2082009
Visuotopic mapping through a multichannel stimulating implant in primate V1
DC Bradley, PR Troyk, JA Berg, M Bak, S Cogan, R Erickson, C Kufta, ...
Journal of neurophysiology 93 (3), 1659-1670, 2005
1962005
Protective overlayer material and electro-optical coating using same
SF Cogan
US Patent 5,530,581, 1996
1761996
Potential-biased, asymmetric waveforms for charge-injection with activated iridium oxide (AIROF) neural stimulation electrodes
SF Cogan, PR Troyk, J Ehrlich, TD Plante, DE Detlefsen
IEEE Transactions on Biomedical Engineering 53 (2), 327-332, 2006
1742006
Sputtered iridium oxide films (SIROFs) for low-impedance neural stimulation and recording electrodes
SF Cogan, TD Plante, J Ehrlich
The 26th Annual International Conference of the IEEE Engineering in Medicine …, 2004
1682004
Retinal prostheses: current challenges and future outlook
JO Winter, SF Cogan, JF Rizzo
Journal of Biomaterials Science, Polymer Edition 18 (8), 1031-1055, 2007
1642007
A hermetic wireless subretinal neurostimulator for vision prostheses
SK Kelly, DB Shire, J Chen, P Doyle, MD Gingerich, SF Cogan, ...
IEEE transactions on biomedical engineering 58 (11), 3197-3205, 2011
1282011
Electrical performance of penetrating microelectrodes chronically implanted in cat cortex
SR Kane, SF Cogan, J Ehrlich, TD Plante, DB McCreery, PR Troyk
IEEE Transactions on Biomedical Engineering 60 (8), 2153-2160, 2013
1242013
Neurotrophin‐eluting hydrogel coatings for neural stimulating electrodes
JO Winter, SF Cogan, JF Rizzo III
Journal of Biomedical Materials Research Part B: Applied Biomaterials: An …, 2007
1172007
The influence of electrolyte composition on the in vitro charge-injection limits of activated iridium oxide (AIROF) stimulation electrodes
SF Cogan, PR Troyk, J Ehrlich, CM Gasbarro, TD Plante
Journal of neural engineering 4 (2), 79, 2007
1022007
Thin film multi-electrode softening cuffs for selective neuromodulation
MA González-González, A Kanneganti, A Joshi-Imre, ...
Scientific reports 8 (1), 16390, 2018
972018
Järjestelmä ei voi suorittaa toimenpidettä nyt. Yritä myöhemmin uudelleen.
Artikkelit 1–20