Hybrid ultra‐low‐field MRI and magnetoencephalography system based on a commercial whole‐head neuromagnetometer PT Vesanen, JO Nieminen, KCJ Zevenhoven, J Dabek, LT Parkkonen, ... Magnetic Resonance in Medicine 69 (6), 1795-1804, 2013 | 131 | 2013 |
Experimental characterization of the electric field distribution induced by TMS devices JO Nieminen, LM Koponen, RJ Ilmoniemi Brain stimulation 8 (3), 582-589, 2015 | 78 | 2015 |
SQUIDs in biomagnetism: a roadmap towards improved healthcare R Körber, JH Storm, H Seton, JP Mäkelä, R Paetau, L Parkkonen, ... Superconductor Science and Technology 29 (11), 113001, 2016 | 70 | 2016 |
Multi-locus transcranial magnetic stimulation—theory and implementation LM Koponen, JO Nieminen, RJ Ilmoniemi Brain stimulation 11 (4), 849-855, 2018 | 57 | 2018 |
Coil optimisation for transcranial magnetic stimulation in realistic head geometry LM Koponen, JO Nieminen, TP Mutanen, M Stenroos, RJ Ilmoniemi Brain stimulation 10 (4), 795-805, 2017 | 55 | 2017 |
Minimum-energy coils for transcranial magnetic stimulation: application to focal stimulation LM Koponen, JO Nieminen, RJ Ilmoniemi Brain stimulation 8 (1), 124-134, 2015 | 55 | 2015 |
Consciousness and cortical responsiveness: a within-state study during non-rapid eye movement sleep JO Nieminen, O Gosseries, M Massimini, E Saad, AD Sheldon, M Boly, ... Scientific Reports 6 (1), 1-10, 2016 | 54 | 2016 |
Recovering TMS-evoked EEG responses masked by muscle artifacts TP Mutanen, M Kukkonen, JO Nieminen, M Stenroos, J Sarvas, ... Neuroimage 139, 157-166, 2016 | 53 | 2016 |
Avoiding eddy-current problems in ultra-low-field MRI with self-shielded polarizing coils JO Nieminen, PT Vesanen, KCJ Zevenhoven, J Dabek, J Hassel, ... Journal of Magnetic Resonance 212 (1), 154-160, 2011 | 53 | 2011 |
Connectivity differences between consciousness and unconsciousness in non-rapid eye movement sleep: a TMS–EEG study M Lee, B Baird, O Gosseries, JO Nieminen, M Boly, BR Postle, G Tononi, ... Scientific reports 9 (1), 1-9, 2019 | 44 | 2019 |
Solving the problem of concomitant gradients in ultra-low-field MRI JO Nieminen, RJ Ilmoniemi Journal of Magnetic Resonance 207 (2), 213-219, 2010 | 34 | 2010 |
All-planar SQUIDs and pickup coils for combined MEG and MRI J Luomahaara, PT Vesanen, J Penttilä, JO Nieminen, J Dabek, J Simola, ... Superconductor Science and Technology 24 (7), 075020, 2011 | 33 | 2011 |
Temperature dependence of relaxation times and temperature mapping in ultra-low-field MRI PT Vesanen, KCJ Zevenhoven, JO Nieminen, J Dabek, LT Parkkonen, ... Journal of magnetic resonance 235, 50-57, 2013 | 31 | 2013 |
The shaky ground truth of real-time phase estimation C Zrenner, D Galevska, JO Nieminen, D Baur, MI Stefanou, U Ziemann Neuroimage 214, 116761, 2020 | 26 | 2020 |
TMS-evoked changes in brain-state dynamics quantified by using EEG data T Mutanen, JO Nieminen, RJ Ilmoniemi Frontiers in human neuroscience 7, 155, 2013 | 26 | 2013 |
Current-density imaging using ultra-low-field MRI with adiabatic pulses JO Nieminen, KCJ Zevenhoven, PT Vesanen, YC Hsu, RJ Ilmoniemi Magnetic Resonance Imaging 32 (1), 54-59, 2014 | 25 | 2014 |
Current-density imaging using ultra-low-field MRI with zero-field encoding PT Vesanen, JO Nieminen, KCJ Zevenhoven, YC Hsu, RJ Ilmoniemi Magnetic Resonance Imaging 32 (6), 766-770, 2014 | 24 | 2014 |
The spatial and temporal distortion of magnetic fields applied inside a magnetically shielded room PT Vesanen, JO Nieminen, KCJ Zevenhoven, J Dabek, J Simola, ... IEEE transactions on magnetics 48 (1), 53-61, 2011 | 23 | 2011 |
An advanced phantom study assessing the feasibility of neuronal current imaging by ultra-low-field NMR R Körber, JO Nieminen, N Höfner, V Jazbinšek, HJ Scheer, K Kim, ... Journal of Magnetic Resonance 237, 182-190, 2013 | 22 | 2013 |
Coil model comparison for cerebellar transcranial magnetic stimulation MK Çan, I Laakso, JO Nieminen, T Murakami, Y Ugawa Biomedical Physics & Engineering Express 5 (1), 015020, 2018 | 18 | 2018 |