PET/MR imaging of bone lesions–implications for PET quantification from imperfect attenuation correction A Samarin, C Burger, SD Wollenweber, DW Crook, IA Burger, DT Schmid, ... European journal of nuclear medicine and molecular imaging 39 (7), 1154-1160, 2012 | 235 | 2012 |
Quiescent period respiratory gating for PET/CT C Liu, A Alessio, L Pierce, K Thielemans, S Wollenweber, A Ganin, ... Medical physics 37 (9), 5037-5043, 2010 | 122 | 2010 |
Quantitative comparison of OSEM and penalized likelihood image reconstruction using relative difference penalties for clinical PET S Ahn, SG Ross, E Asma, J Miao, X Jin, L Cheng, SD Wollenweber, ... Physics in Medicine & Biology 60 (15), 5733, 2015 | 107 | 2015 |
Comparison of 4-class and continuous fat/water methods for whole-body, MR-based PET attenuation correction SD Wollenweber, S Ambwani, AHR Lonn, DD Shanbhag, ... IEEE Transactions on Nuclear Science 60 (5), 3391-3398, 2013 | 98 | 2013 |
Evaluation of an atlas-based PET head attenuation correction using PET/CT & MR patient data SD Wollenweber, S Ambwani, G Delso, AHR Lonn, R Mullick, F Wiesinger, ... IEEE Transactions on Nuclear Science 60 (5), 3383-3390, 2013 | 88 | 2013 |
Comparison of Hotelling observer models and human observers in defect detection from myocardial SPECT imaging SD Wollenweber, BMW Tsui, DS Lalush, EC Frey, KJ LaCroix, ... IEEE Transactions on Nuclear Science 46 (6), 2098-2103, 1999 | 88 | 1999 |
Parameterization of a model-based 3-D PET scatter correction SD Wollenweber IEEE Transactions on Nuclear Science 49 (3), 722-727, 2002 | 64 | 2002 |
Methods for automatic protocol selection SD Wollenweber, CW Stearns, DM Miesbauer US Patent 7,542,792, 2009 | 61 | 2009 |
Motion compensation in image processing G Gopalakrishnan, A Ganin, RM Majeshwar, KFJJ Thielemans, ... US Patent 9,129,426, 2015 | 49 | 2015 |
Methods and systems for assessing patient movement in diagnostic imaging SD Wollenweber US Patent 8,107,695, 2012 | 48 | 2012 |
Measured count-rate performance of the Discovery STE PET/CT scanner in 2D, 3D and partial collimation acquisition modes LR MacDonald, RE Schmitz, AM Alessio, SD Wollenweber, CW Stearns, ... Physics in Medicine & Biology 53 (14), 3723, 2008 | 44 | 2008 |
Dose Optimization in TOF-PET/MR Compared to TOF-PET/CT MA Queiroz, G Delso, S Wollenweber, T Deller, K Zeimpekis, M Huellner, ... PLoS One 10 (7), e0128842, 2015 | 38 | 2015 |
Comparison of different methods for data-driven respiratory gating of PET data K Thielemans, P Schleyer, PK Marsden, RM Manjeshwar, ... 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS …, 2013 | 38 | 2013 |
Clinical evaluation of a block sequential regularized expectation maximization reconstruction algorithm in 18F-FDG PET/CT studies BR Sah, P Stolzmann, G Delso, SD Wollenweber, M Hüllner, YA Hakami, ... Nuclear medicine communications 38 (1), 57-66, 2017 | 37 | 2017 |
System and method for generating PET-CT images V Shanmugam, MM Hussaini, SD Wollenweber, MG Bonner US Patent 7,447,345, 2008 | 36 | 2008 |
Systems and methods for correcting a positron emission tomography emission image SD Wollenweber, A Ganin US Patent 7,507,968, 2009 | 34 | 2009 |
System and method for table/gantry alignment in imaging systems SD Wollenweber US Patent 6,917,666, 2005 | 33 | 2005 |
Sign determination methods for the respiratory signal in data-driven PET gating O Bertolli, S Arridge, SD Wollenweber, CW Stearns, BF Hutton, ... Physics in Medicine & Biology 62 (8), 3204, 2017 | 29 | 2017 |
Multi modality imaging methods and apparatus SD Wollenweber, AHR Lonn, CW Stearns, DM Miesbauer, KM Littlejohn US Patent 7,348,564, 2008 | 29 | 2008 |
Method and system for estimating scatter in a pet scanner SD Wollenweber US Patent 6,590,213, 2003 | 26 | 2003 |