Follow
Alexandre Santos
Alexandre Santos
Royal Adelaide Hospital
Verified email at adelaide.edu.au
Title
Cited by
Cited by
Year
Lightweight Bismuth Titanate (Bi4Ti3O12) Nanoparticle-Epoxy Composite for Advanced Lead-Free X-ray Radiation Shielding
L Yu, PL Yap, A Santos, D Tran, D Losic
ACS Applied Nano Materials 4 (7), 7471-7478, 2021
392021
Characterisation of a real-time fibre-coupled beryllium oxide (BeO) luminescence dosimeter in X-ray beams
AMC Santos, M Mohammadi, J Asp, TM Monro, S Afshar
Radiation measurements 53, 1-7, 2013
372013
Risk of second primary cancer after breast cancer treatment
LG Marcu, A Santos, E Bezak
European Journal of Cancer Care 23 (1), 51-64, 2014
362014
Risk estimation of second primary cancers after breast radiotherapy
EB Alexandre M. C. Santos, Loredana G. Marcu, Chia M. Wong
Acta Oncologica, 2016
322016
Investigation of a fibre-coupled beryllium oxide (BeO) ceramic luminescence dosimetry system
AMC Santos, M Mohammadi, S Afshar
Radiation measurements 70, 52-58, 2014
272014
Bismuth Oxide Films for X-ray shielding: Effects of particle size and structural morphology
L Yu, ALC Pereira, DNH Tran, AMC Santos, D Losic
Materials Chemistry and Physics 260, 124084, 2021
252021
Energy dependency of a water-equivalent fibre-coupled beryllium oxide (BeO) dosimetry system
AMC Santos, M Mohammadi, S Afshar
Radiation Measurements 73, 1-6, 2015
192015
Robust Volume Calculations of Tumors of Various Sizes.
AP Peskin, K Kafadar, AM Santos, G Haemer
IPCV, 3-9, 2009
182009
Evaluation of a real‐time BeO ceramic fiber‐coupled luminescence dosimetry system for dose verification of high dose rate brachytherapy
AMC Santos, M Mohammadi, S Afshar V
Medical Physics 42 (11), 6349-6356, 2015
172015
Application of optical photogrammetry in radiation oncology: HDR surface mold brachytherapy
MJJ Douglass, AMC Santos
Brachytherapy 18 (5), 689-700, 2019
152019
High-yield preparation of edge-functionalized and water dispersible few-layers of hexagonal boron nitride (hBN) by direct wet chemical exfoliation
L Yu, PL Yap, DNH Tran, AMC Santos, D Losic
Nanotechnology 32 (40), 405601, 2021
112021
Radiation dose calculation in 3D heterogeneous media using artificial neural networks
J Keal, A Santos, S Penfold, M Douglass
Medical Physics 48 (5), 2637-2645, 2021
102021
Evaluation of camera settings for photogrammetric reconstruction of humanoid phantoms for EBRT bolus and HDR surface brachytherapy applications
CA Bridger, MJJ Douglass, PD Reich, AMC Santos
Physical and Engineering Sciences in Medicine 44 (2), 457-471, 2021
92021
Will COVID-19 change the way we teach medical physics post pandemic?
A Haworth, AL Fielding, S Marsh, P Rowshanfarzad, A Santos, P Metcalfe, ...
Physical and engineering sciences in medicine 43, 735-738, 2020
92020
Evaluation of a real-time optically stimulated luminescence beryllium oxide (BeO) fibre-coupled dosimetry system with a superficial 140 kVp X-ray beam
AMC Santos, R Gowda, E Bezak, S Afshar
Physica Medica 65, 167-171, 2019
72019
Robust estimation of censored mixture models
AM Santos
University of Colorado at Denver, 2011
72011
Lightweight polyester fabric with elastomeric bismuth titanate composite for high-performing lead-free X-ray shielding
L Yu, PL Yap, AMC Santos, DNH Tran, D Losic
Radiation Physics and Chemistry 205, 110726, 2023
62023
The role of hypofractionation in proton therapy
A Santos, S Penfold, P Gorayski, H Le
Cancers 14 (9), 2271, 2022
62022
Estimating the second primary cancer risk due to proton therapy compared to hybrid IMRT for left sided breast cancer
AMC Santos, A Kotsanis, L Cunningham, SN Penfold
Acta Oncologica 60 (3), 300-304, 2021
62021
Digital workflow for full-arch implant-supported prosthesis based on intraoral scans of a relative of the patient
ADT Neto, AJ de Moura e Costa, IGG Choi, A Santos, JF Dos Santos, ...
Journal of Oral Implantology 47 (1), 68-71, 2021
62021
The system can't perform the operation now. Try again later.
Articles 1–20