Influence of femoral head size on impingement, dislocation and stress distribution in total hip replacement D Kluess, H Martin, W Mittelmeier, KP Schmitz, R Bader Medical engineering & physics 29 (4), 465-471, 2007 | 245 | 2007 |
Effects of titanium particle size on osteoblast functions in vitro and in vivo MG Choi, HS Koh, D Kluess, D O'Connor, A Mathur, GA Truskey, J Rubin, ... Proceedings of the National Academy of Sciences 102 (12), 4578-4583, 2005 | 140 | 2005 |
A convenient approach for finite-element-analyses of orthopaedic implants in bone contact: modeling and experimental validation D Kluess, R Souffrant, W Mittelmeier, A Wree, KP Schmitz, R Bader Computer methods and programs in biomedicine 95 (1), 23-30, 2009 | 130 | 2009 |
Limited range of motion of hip resurfacing arthroplasty due to unfavorable ratio of prosthetic head size and femoral neck diameter D Kluess, C Zietz, T Lindner, W Mittelmeier, KP Schmitz, R Bader Acta orthopaedica 79 (6), 748-754, 2008 | 84 | 2008 |
Finite element analysis in orthopaedic biomechanics D Kluess Finite element analysis, 2010 | 54 | 2010 |
The influence of head diameter and wall thickness on deformations of metallic acetabular press-fit cups and UHMWPE liners: a finite element analysis P Goebel, D Kluess, J Wieding, R Souffrant, H Heyer, M Sander, R Bader Journal of Orthopaedic Science 18, 264-270, 2013 | 48 | 2013 |
The importance of wear couples for younger endoprosthesis patients J Kircher, P Bergschmidt, R Bader, D Kluess, E Besser-Mahuzir, A Leder, ... Der Orthopäde 36, 337-346, 2007 | 42* | 2007 |
Interlaboratory comparison of femur surface reconstruction from CT data compared to reference optical 3D scan E Soodmand, D Kluess, PA Varady, R Cichon, M Schwarze, D Gehweiler, ... Biomedical engineering online 17, 1-10, 2018 | 41 | 2018 |
Relationship between mechanical properties and bone mineral density of human femoral bone retrieved from patients with osteoarthritis Y Haba, T Lindner, A Fritsche, AK Schiebenhöfer, R Souffrant, D Kluess, ... The open orthopaedics journal 6, 458, 2012 | 38 | 2012 |
Intraoperative impaction of total knee replacements: An explicit finite-element-analysis of principal stresses in ceramic vs. cobalt–chromium femoral components D Kluess, W Mittelmeier, R Bader Clinical Biomechanics 25 (10), 1018-1024, 2010 | 35 | 2010 |
A round-robin finite element analysis of human femur mechanics between seven participating laboratories with experimental validation D Kluess, E Soodmand, A Lorenz, D Pahr, M Schwarze, R Cichon, ... Computer Methods in Biomechanics and Biomedical Engineering, 2019 | 30 | 2019 |
Investigation of the inverse piezoelectric effect of trabecular bone on a micrometer length scale using synchrotron radiation DCF Wieland, C Krywka, E Mick, R Willumeit-Römer, R Bader, D Kluess Acta biomaterialia 25, 339-346, 2015 | 27 | 2015 |
Investigation of an acoustic-mechanical method to detect implant loosening C Ruther, H Nierath, H Ewald, JL Cunningham, W Mittelmeier, R Bader, ... Medical engineering & physics 35 (11), 1669-1675, 2013 | 27 | 2013 |
Prospective comparative clinical study of ceramic and metallic femoral components for total knee arthroplasty over a five-year follow-up period P Bergschmidt, M Ellenrieder, R Bader, D Kluess, S Finze, B Schwemmer, ... The Knee 23 (5), 871-876, 2016 | 26 | 2016 |
Reporting checklist for verification and validation of finite element analysis in orthopedic and trauma biomechanics C Oefner, S Herrmann, M Kebbach, HE Lange, D Kluess, M Woiczinski Medical Engineering & Physics 92, 25-32, 2021 | 25 | 2021 |
Surgically relevant morphological parameters of proximal human femur: a statistical analysis based on 3D reconstruction of CT data E Soodmand, G Zheng, W Steens, R Bader, L Nolte, D Kluess Orthopaedic surgery 11 (1), 135-142, 2019 | 25 | 2019 |
Ceramic total knee arthroplasty: ready to go? G Solarino, C Piconi, V De Santis, A Piazzolla, B Moretti Joints 5 (04), 224-228, 2017 | 25 | 2017 |
Effect of surgical parameters on the biomechanical behaviour of bicondylar total knee endoprostheses–A robot-assisted test method based on a musculoskeletal model M Kebbach, R Grawe, A Geier, E Winter, P Bergschmidt, D Kluess, ... Scientific reports 9 (1), 14504, 2019 | 24 | 2019 |
HiL simulation for testing joint stability after total knee arthroplasty S Herrmann, C Woernle, M Kaehler, R Rachholz, R Souffrant, J Zierath, ... Multibody System Dynamics 28, 55-67, 2012 | 24 | 2012 |
A novel sensor concept for optimization of loosening diagnostics in total hip replacement C Ruther, H Ewald, W Mittelmeier, A Fritsche, R Bader, D Kluess | 24 | 2011 |