Follow
Paweł Kowalski
Paweł Kowalski
PhD student, National Centre for Nuclear Research
Verified email at ncbj.gov.pl - Homepage
Title
Cited by
Cited by
Year
Test of a single module of the J-PET scanner based on plastic scintillators
P Moskal, S Niedźwiecki, T Bednarski, E Czerwiński, E Kubicz, I Moskal, ...
Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2014
2122014
Time resolution of the plastic scintillator strips with matrix photomultiplier readout for J-PET tomograph
P Moskal, O Rundel, D Alfs, T Bednarski, P Białas, E Czerwiński, A Gajos, ...
Physics in Medicine & Biology 61 (5), 2025, 2016
1712016
Feasibility study of the positronium imaging with the J-PET tomograph
P Moskal, D Kisielewska, C Curceanu, E Czerwiński, K Dulski, A Gajos, ...
Physics in Medicine & Biology 64 (5), 055017, 2019
1672019
J-PET: a new technology for the whole-body PET imaging
S Niedźwiecki, P Białas, C Curceanu, E Czerwiński, K Dulski, A Gajos, ...
arXiv preprint arXiv:1710.11369, 2017
1542017
A novel method for the line-of-response and time-of-flight reconstruction in TOF-PET detectors based on a library of synchronized model signals
P Moskal, N Zoń, T Bednarski, P Białas, E Czerwiński, A Gajos, ...
Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2015
1462015
Multichannel FPGA based MVT system for high precision time (20 ps RMS) and charge measurement
M Pałka, P Strzempek, G Korcyl, T Bednarski, S Niedźwiecki, P Białas, ...
Journal of Instrumentation 12 (08), P08001, 2017
972017
Potential of the J-PET detector for studies of discrete symmetries in decays of positronium atom: a purely leptonic system
P Moskal, D Alfs, T Bednarski, P Białas, E Czerwiński, C Curceanu, ...
Acta Physica Polonica. B 47 (2), 2016
962016
A feasibility study of ortho-positronium decays measurement with the J-PET scanner based on plastic scintillators
D Kamińska, A Gajos, E Czerwiński, D Alfs, T Bednarski, P Białas, ...
The European Physical Journal C 76, 1-14, 2016
932016
Novel method for hit-position reconstruction using voltage signals in plastic scintillators and its application to Positron Emission Tomography
L Raczyński, P Moskal, P Kowalski, W Wiślicki, T Bednarski, P Białas, ...
Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2014
912014
Evaluation of single-chip, real-time tomographic data processing on FPGA SoC devices
G Korcyl, P Białas, C Curceanu, E Czerwiński, K Dulski, B Flak, A Gajos, ...
IEEE transactions on medical imaging 37 (11), 2526-2535, 2018
872018
Compressive sensing of signals generated in plastic scintillators in a novel J-PET instrument
L Raczyński, P Moskal, P Kowalski, W Wiślicki, T Bednarski, P Białas, ...
Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2015
842015
Estimating the NEMA characteristics of the J-PET tomograph using the GATE package
P Kowalski, W Wiślicki, RY Shopa, L Raczyński, K Klimaszewski, ...
Physics in Medicine & Biology 63 (16), 165008, 2018
772018
Trilateration-based reconstruction of ortho-positronium decays into three photons with the J-PET detector
A Gajos, D Kamińska, E Czerwiński, D Alfs, T Bednarski, P Białas, ...
Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2016
762016
Feasibility studies of the polarization of photons beyond the optical wavelength regime with the J-PET detector
P Moskal, N Krawczyk, BC Hiesmayr, M Bała, C Curceanu, E Czerwiński, ...
The European Physical Journal C 78, 1-9, 2018
602018
Performance assessment of the 2 γpositronium imaging with the total-body PET scanners
P Moskal, D Kisielewska, R Y. Shopa, Z Bura, J Chhokar, C Curceanu, ...
EJNMMI physics 7, 1-16, 2020
582020
Sampling FEE and Trigger-less DAQ for the J-PET Scanner
G Korcyl, D Alfs, T Bednarski, P Białas, E Czerwiński, K Dulski, A Gajos, ...
arXiv preprint arXiv:1602.05251, 2016
582016
Calculation of the time resolution of the J-PET tomograph using kernel density estimation
L Raczyński, W Wiślicki, W Krzemień, P Kowalski, D Alfs, T Bednarski, ...
Physics in Medicine & Biology 62 (12), 5076, 2017
512017
Measurement of gamma quantum interaction point in plastic scintillator with WLS strips
J Smyrski, D Alfs, T Bednarski, P Białas, E Czerwiński, K Dulski, A Gajos, ...
Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2017
492017
Determination of the 3\gamma fraction from positron annihilation in mesoporous materials for symmetry violation experiment with J-PET scanner
B Jasińska, M Gorgol, M Wiertel, R Zaleski, D Alfs, T Bednarski, P Białas, ...
arXiv preprint arXiv:1602.05376, 2016
482016
Human tissues investigation using PALS technique
B Jasińska, B Zgardzińska, G Chołubek, M Gorgol, K Wiktor, K Wysogld, ...
arXiv preprint arXiv:1711.04512, 2017
472017
The system can't perform the operation now. Try again later.
Articles 1–20