Implantable glucose sensor GS Wilson, DS Bindra, BS Hill, DR Thevenot, R Sternberg, G Reach, ... US Patent 5,165,407, 1992 | 1562 | 1992 |
Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring DS Bindra, Y Zhang, GS Wilson, R Sternberg, DR Thevenot, D Moatti, ... Analytical Chemistry 63 (17), 1692-1696, 1991 | 943 | 1991 |
Study and development of multilayer needle-type enzyme-based glucose microsensors R Sternberg, MB Barrau, L Gangiotti, DR Thévenot, DS Bindra, GS Wilson, ... Biosensors 4 (1), 27-40, 1989 | 871 | 1989 |
Progress toward the development of an implantable sensor for glucose GS Wilson, Y Zhang, G Reach, D Moatti-Sirat, V Poitout, DR Thévenot, ... Clinical Chemistry 38 (9), 1613-1617, 1992 | 820 | 1992 |
Can continuous glucose monitoring be used for the treatment of diabetes G Reach, GS Wilson Analytical chemistry 64 (6), 381A-386A, 1992 | 809 | 1992 |
Strategies for calibrating a subcutaneous glucose sensor. G Velho, P Froguel, DR Thevenot, G Reach Biomedica Biochimica Acta 48 (11-12), 957-964, 1989 | 732 | 1989 |
A glucose monitoring system for on line estimation in man of blood glucose concentration using a miniaturized glucose sensor implanted in the subcutaneous tissue and a wearable … V Poitout, D Moatti-Sirat, G Reach, Y Zhang, GS Wilson, F Lemonnier, ... Diabetologia 36, 658-663, 1993 | 711 | 1993 |
Evaluating in vitro and in vivo the interference of ascorbate and acetaminophen on glucose detection by a needle-type glucose sensor D Moatti-Sirat, G Velho, G Reach Biosensors and Bioelectronics 7 (5), 345-352, 1992 | 514 | 1992 |
Towards continuous glucose monitoring: in vivo evaluation of a miniaturized glucose sensor implanted for several days in rat subcutaneous tissue D Moatti-Sirat, F Capron, V Poitout, G Reach, DS Bindra, Y Zhang, ... Diabetologia 35, 224-230, 1992 | 501 | 1992 |
Elimination of the acetaminophen interference in an implantable glucose sensor Y Zhang, Y Hu, GS Wilson, D Moatti-Sirat, V Poitout, G Reach Analytical Chemistry 66 (7), 1183-1188, 1994 | 452 | 1994 |
Which threshold to detect hypoglycemia? Value of receiver-operator curve analysis to find a compromise between sensitivity and specificity G Reach Diabetes Care 24 (5), 803, 2001 | 414 | 2001 |
In vitro and in vivo evaluation in dogs of a miniaturized glucose sensor V POITOUT, D MOATTI, G VELHO, G REACH, R STERNBERG, ... ASAIO Journal 37 (3), M298-M300, 1991 | 409 | 1991 |
Reduction of acetaminophen interference in glucose sensors by a composite Nafion membrane: demonstration in rats and man D Moatti-Sirat, V Poitout, V Thome, MN Gangnerau, Y Zhang, Y Hu, ... Diabetologia 37, 610-616, 1994 | 401 | 1994 |
A user-friendly method for calibrating a subcutaneous glucose sensor-based hypoglycaemic alarm B Aussedat, V Thome-Duret, G Reach, F Lemmonier, JC Klein, Y Hu, ... Biosensors and Bioelectronics 12 (11), 1061-1070, 1997 | 390 | 1997 |
A method for evaluating in vivo the functional characteristics of glucose sensors G Reach, P Abel, U Fischer Biosensors 2 (4), 211-220, 1986 | 381 | 1986 |
In vitro and in vivo stability of electrode potentials in needle-type glucose sensors: influence of needle material G Velho, P Froguel, R Sternberg, DR Thevenot, G Reach Diabetes 38 (2), 164-171, 1989 | 360 | 1989 |
Calibration in dogs of a subcutaneous miniaturized glucose sensor using a glucose meter for blood glucose determination V Poitout, D Moatti-Sirat, G Reach Biosensors and Bioelectronics 7 (8), 587-592, 1992 | 329 | 1992 |
Physiological differences between interstitial glucose and blood glucose measured in human subjects E Kulcu, JA Tamada, G Reach, RO Potts, MJ Lesho Diabetes care 26 (8), 2405-2409, 2003 | 323 | 2003 |
PPAR-α–null mice are protected from high-fat diet–induced insulin resistance M Guerre-Millo, C Rouault, P Poulain, J André, V Poitout, JM Peters, ... Diabetes 50 (12), 2809-2814, 2001 | 313 | 2001 |
Calibration of a subcutaneous amperometric glucose sensor implanted for 7 days in diabetic patients: Part 2. Superiority of the one-point calibration method C Choleau, JC Klein, G Reach, B Aussedat, V Demaria-Pesce, GS Wilson, ... Biosensors and Bioelectronics 17 (8), 647-654, 2002 | 290 | 2002 |