Accelerating GluCEST imaging using deep learning for B0 correction Y Li, D Xie, A Cember, RPR Nanga, H Yang, D Kumar, H Hariharan, L Bai, ... Magnetic resonance in medicine 84 (4), 1724-1733, 2020 | 29 | 2020 |
Integrating 1H MRS and deuterium labeled glucose for mapping the dynamics of neural metabolism in humans ATJ Cember, NE Wilson, LJ Rich, P Bagga, RPR Nanga, S Swago, ... Neuroimage 251, 118977, 2022 | 21 | 2022 |
Recovery kinetics of creatine in mild plantar flexion exercise using 3D creatine CEST imaging at 7 Tesla D Kumar, RPR Nanga, D Thakuri, N Wilson, A Cember, ML Martin, D Zhu, ... Magnetic resonance in medicine 85 (2), 802-817, 2021 | 19 | 2021 |
Glutamate dehydrogenase: role in regulating metabolism and insulin release in pancreatic β-cells DF Wilson, ATJ Cember, FM Matschinsky Journal of Applied Physiology 125 (2), 419-428, 2018 | 19 | 2018 |
Glutamate‐weighted CEST (gluCEST) imaging for mapping neurometabolism: An update on the state of the art and emerging findings from in vivo applications ATJ Cember, RPR Nanga, R Reddy NMR in Biomedicine 36 (6), e4780, 2023 | 16 | 2023 |
The thermodynamic basis of glucose‐stimulated insulin release: a model of the core mechanism DF Wilson, ATJ Cember, FM Matschinsky Physiological Reports 5 (12), e13327, 2017 | 16 | 2017 |
Improved method for post‐processing correction of B1 inhomogeneity in glutamate‐weighted CEST images of the human brain ATJ Cember, H Hariharan, D Kumar, RPR Nanga, R Reddy NMR in Biomedicine 34 (6), e4503, 2021 | 12 | 2021 |
Glutamate-weighted magnetic resonance imaging (GluCEST) detects effects of transcranial magnetic stimulation to the motor cortex ATJ Cember, BL Deck, A Kelkar, O Faseyitan, JP Zimmerman, B Erickson, ... Neuroimage 256, 119191, 2022 | 10 | 2022 |
Membrane affinity of platensimycin and its dialkylamine analogs I Rowe, M Guo, A Yasmann, A Cember, HO Sintim, S Sukharev International Journal of Molecular Sciences 16 (8), 17909-17932, 2015 | 8 | 2015 |
Repeatability of B1+ inhomogeneity correction of volumetric (3D) glutamate CEST via High‐permittivity dielectric padding at 7T PS Jacobs, B Benyard, A Cember, RPR Nanga, Q Cao, MD Tisdall, ... Magnetic resonance in medicine 88 (6), 2475-2484, 2022 | 4 | 2022 |
Quantification of cross‐relaxation in downfield 1H MRS at 7 T in human calf muscle S Swago, MA Elliott, RPR Nanga, NE Wilson, A Cember, R Reddy, ... Magnetic Resonance in Medicine 90 (1), 11-20, 2023 | 3 | 2023 |
Age-dependent variation in CEST signal at low B1 may reflect decline of lipids in older brain tissue ATJ Cember, P Bagga, H Hariharan, R Reddy ISMRM & SMRT Virtual Conference 190, 2020 | 3 | 2020 |
Feasibility of partial 3D GluCEST in healthy human adults at 7.0 T RPR Nanga, ATJ Cember, D Thakuri, D Kumar, NE Wilson, H Hariharan, ... Proc Annu Meet Int Soc Magn Reson Med, 2019 | 2 | 2019 |
Towards a robust and reproducible GluCEST analysis pipeline J Jee, RPR Nanga, A Cember, P Jacobs, H Robinson, MA Elliott, R Reddy, ... Proceedings of the Annual Meeting of the International Society for Magnetic …, 2022 | 1 | 2022 |
Volumetric glutamate-weighted MR imaging (gluCEST) enables in vivo detection of metabolic differences between human hippocampal subfields ATJ Cember, RPR Nanga, H Hariharan, NE Wilson, P Bagga, R Reddy Proceedings of the Annual Meeting of the International Society for Magnetic …, 2021 | 1 | 2021 |
Using glutamate-weighted MR imaging (GluCEST) to detect effects of transcranial magnetic stimulation ATJ Cember, B Deck, J Zimmerman, B Erickson, A Kelkar, O Faseyitan, ... Proceedings of the Annual Meeting of the International Society for Magnetic …, 2021 | 1 | 2021 |
Imaging Glutamate in the Human Brain at Ultra-High Magnetic Field: Advances and Applications ATJ Cember University of Pennsylvania, 2021 | 1 | 2021 |
Assessing gray and white matter glutamatergic turnover in human brain non-invasivley using 1 H MRS and deuterated glucose P Bagga, LJ Rich, ATJ Cember, RPR Nanga, D Thakuri, M Elliott, M Haris, ... Proceedings of the International Society for Magnetic Resonance in Medicine, 2020 | 1 | 2020 |
A tailored functional form for increased accuracy in CEST B1 calibration curves ATJ Cember, H Hariharan, R Reddy Proceedings of the Annual Meeting of the International Society for Magnetic …, 2018 | 1 | 2018 |
Glutamate-weighted CEST (GluCEST) MRI contrast at the site of transcranial magnetic stimulation is related to changes in motor evoked potentials (P3. 1-019) J Medaglia, A Cember, R Nanga, H Hariharan, B Erickson, A Kelkar, ... Neurology 92 (15 Supplement), 2019 | | 2019 |