Validation and application of a computational model for wrist and hand movements using surface markers CD Metcalf, SV Notley, PH Chappell, JH Burridge, VT Yule IEEE Transactions on Biomedical Engineering 55 (3), 1199-1210, 2008 | 117 | 2008 |
Case studies to demonstrate the range of applications of the Southampton Hand Assessment Procedure PJ Kyberd, A Murgia, M Gasson, T Tjerks, C Metcalf, PH Chappell, ... British Journal of Occupational Therapy 72 (5), 212-218, 2009 | 116 | 2009 |
Markerless motion capture and measurement of hand kinematics: validation and application to home-based upper limb rehabilitation. C Metcalf, R Robinson, A Malpass, T Bogle, T Dell, C Harris, S Demain IEEE Transactions on Biomedical Engineering 60 (8), 2184-2192, 2013 | 101 | 2013 |
A review of clinical upper limb assessments within the framework of the WHO ICF C Metcalf, J Adams, J Burridge, V Yule, P Chappell Musculoskeletal care 5 (3), 160-173, 2007 | 86 | 2007 |
Methodologies to assess muscle co-contraction during gait in people with neurological impairment–a systematic literature review MCN Rosa, A Marques, S Demain, CD Metcalf, J Rodrigues Journal of Electromyography and Kinesiology 24 (2), 179-191, 2014 | 56 | 2014 |
A narrative review on haptic devices: relating the physiology and psychophysical properties of the hand to devices for rehabilitation in central nervous system disorders S Demain, CD Metcalf, GV Merrett, D Zheng, S Cunningham Disability and Rehabilitation: Assistive Technology 8 (3), 181-189, 2013 | 54 | 2013 |
Lower limb co-contraction during walking in subjects with stroke: A systematic review MCN Rosa, A Marques, S Demain, CD Metcalf Journal of Electromyography and Kinesiology 24 (1), 1-10, 2014 | 50 | 2014 |
Proximal interphalangeal joint replacement in patients with arthritis of the hand: a meta-analysis J Adams, C Ryall, A Pandyan, C Metcalf, M Stokes, S Bradley, ... The Journal of bone and joint surgery. British volume 94 (10), 1305-1312, 2012 | 38 | 2012 |
Changes in hand function with age and normative unimpaired scores when measured with the Southampton Hand Assessment Procedure C D Metcalf, H Woodward, V Wright, P H Chappell, J H Burridge, V T Yule The British Journal of Hand Therapy 13 (3), 79-83, 2008 | 31 | 2008 |
Fast gait speed and self-perceived balance as valid predictors and discriminators of independent community walking at 6 months post-stroke–a preliminary study MC Rosa, A Marques, S Demain, CD Metcalf Disability and rehabilitation 37 (2), 129-134, 2015 | 30 | 2015 |
Complex hand dexterity: a review of biomechanical methods for measuring musical performance CD Metcalf, TA Irvine, JL Sims, YL Wang, AWY Su, DO Norris Frontiers in psychology 5, 414, 2014 | 29 | 2014 |
A systematic review of the key factors affecting tissue viability and rehabilitation outcomes of the residual limb in lower extremity traumatic amputees K Butler, C Bowen, AM Hughes, R Torah, I Ayala, J Tudor, CD Metcalf Journal of Tissue Viability 23 (3), 81-93, 2014 | 28 | 2014 |
Fabric-based strain sensors for measuring movement in wearable telemonitoring applications CD Metcalf, SR Collie, AW Cranny, G Hallett, C James, J Adams, ... IET Digital Library, 2009 | 27 | 2009 |
Modified kinematic technique for measuring pathological hyperextension and hypermobility of the interphalangeal joints C Metcalf, S Notley Biomedical Engineering, IEEE Transactions on 58 (5), 1224-1231, 2011 | 21 | 2011 |
Knee posture during gait and global functioning post-stroke: a theoretical ICF framework using current measures in stroke rehabilitation MCN Rosa, A Marques, S Demain, CD Metcalf Disability and rehabilitation 37 (10), 904-913, 2015 | 15 | 2015 |
Incorporation of Early Career Researchers within multidisciplinary research at academic institutions AJ Sobey, NC Townsend, CD Metcalf, KD Bruce, FM Fazi Research Evaluation 22 (3), 169-178, 2013 | 12 | 2013 |
Design and qualitative evaluation of tactile devices for stroke rehabilitation GV Merrett, CD Metcalf, D Zheng, S Cunningham, S Barrow, SH Demain IET Digital Library, 2011 | 11 | 2011 |
The relationship between movement and function of the wrist and hand: A clinically focused kinematic study C Metcalf University of Southampton, 2008 | 10 | 2008 |
Southampton hand assessment procedure (SHAP) C Metcalf | 9 | 2015 |
Test-retest reliability of the Southampton hand assessment procedure J Adams, K Hodges, J Kujawa, C Metcalf International Journal of Rehabilitation Research 32, S18, 2009 | 7 | 2009 |