Teemu Näykki
NimikeViittauksetVuosi
Handbook for calculation of measurement uncertainty in environmental laboratories
B Magnusson, T Näykki, H Hovind, M Krysell
Nordtest Report TR537, 2003
1862003
Handbook for calculation of measurement uncertainty in environmental laboratories
B Magnusson
1762003
Optimization of a flow injection hydride generation atomic absorption spectrometric method for the determination of arsenic, antimony and selenium in iron chloride/sulfate …
T Näykki, P Perämäki, J Kujala, A Mikkonen
Analytica chimica acta 439 (2), 229-238, 2001
562001
Dissolved oxygen concentration interlaboratory comparison: what can we learn?
T Näykki, L Jalukse, I Helm, I Leito
Water 5 (2), 420-442, 2013
262013
Software support for the Nordtest method of measurement uncertainty evaluation
T Näykki, A Virtanen, I Leito
Accreditation and quality assurance 17 (6), 603-612, 2012
142012
Handbook of calculation of measurement uncertainty in environmental laboratories, 2nd edn. NORDTEST report TR537
B Magnusson, T Näykki, H Hovind, M Krysell
12*2004
Validation of a new measuring system for water turbidity field measurements
T Näykki, S Koponen, T Väisänen, T Pyhälahti, T Toivanen, I Leito
Accreditation and Quality Assurance 19 (3), 175-183, 2014
112014
Handbook for calculation of measurement uncertainty in environmental laboratories (NT TR 537-Edition 3.1)
B Magnusson, T Naykki, H Hovinol
Nordic Innovation, 2012
72012
Laatusuositukset ympäristöhallinnon vedenlaaturekistereihin vietävälle tiedolle. Vesistä tehtävien analyyttien määritysrajat, mittaus-epävarmuudet sekä säilytysajat ja-tavat.-2 …
T Näykki, T Väisänen
http://hdl. handle. net/10138/163532, 2016
52016
Application of the Nordtest method for “real-time” uncertainty estimation of on-line field measurement
T Näykki, A Virtanen, L Kaukonen, B Magnusson, T Väisänen, I Leito
Environmental monitoring and assessment 187 (10), 630, 2015
52015
Comparison of measurement uncertainty estimates using quality control and validation data.
T Näykki, B Magnusson, I Helm, L Jalukse, T Väisänen, I Leito
Journal of Chemical Metrology 8 (1), 2014
52014
NORDTEST Report TR 537. Handbook for calculation of measurement uncertainty in Environmental Laboratories
B Magnusson, T Naykki, H Hovind, M Krysell
2004-02)[2016-04-07]. http://www. doc88. com/p-3397504798587. html, 2004
52004
Proficiency test of pH, conductivity and dissolved oxygen concentration field measurements in river water
T Näykki, M Leivuori, K Björklöf, R Väisänen, M Laine, T Väisänen, I Leito
Accreditation and Quality Assurance 19 (4), 259-268, 2014
42014
The effect of gypsum on phosphorus losses at the catchment scale
P Ekholm, E Jaakkola, M Kiirikki, K Lahti, J Lehtoranta, V Mäkelä, ...
The Finnish Environment, 47, 2011
42011
Determination of Na2O from sodium aluminate NaAlO2
T Näykki, R Anttila, P Perämäki, A Kurikka, P Nikula
Talanta 52 (4), 755-760, 2000
42000
Handbook for calculation of measurement uncertainty in environmental laboratories, NordTest Report
B Magnuss, T Näykki, H Hovind, M Krysell
TR 537, Approved 2004-02, 2017
32017
Software support for the Nordtest method of measurement uncertainty evaluation
T Naykki, A Virtanen, I Leito
Accreditation and Quality Assurance 17 (6), 603-612, 2012
22012
Verkostomainen yhteistyö ympäristöhallinnon laboratoriotoiminnan menestystekijänä
M Luotola, R Pehkonen, T Näykki, T Väisänen
Suomen ympäristökeskuksen raportteja 25, 2012, 2012
22012
Handbook for Calculation of Measurement Uncertainty in Environmental Laboratories, Nordtest
B Magnusson, T Näykki, H Hovind, M Krysell
NT Technical Report 537, NT Project, 2011
22011
Antureiden kalibrointi ja ainepitoisuuksien jatkuva seuranta sameusanturin avulla
H Arola, L Arvola, N Kotamäki, H Kotilainen, J Linjama, T Näykki
Jatkuvatoiminen sameusmittaus: Hyvät mittauskäytännöt ja aineistonkäsittely …, 2012
12012
Järjestelmä ei voi suorittaa toimenpidettä nyt. Yritä myöhemmin uudelleen.
Artikkelit 1–20