Follow
Sinyeob Ahn
Sinyeob Ahn
Siemens Healthineers, U.S.A.
Verified email at siemens-healthineers.com
Title
Cited by
Cited by
Year
Simultaneous imaging of locus coeruleus and substantia nigra with a quantitative neuromelanin MRI approach
X Chen, DE Huddleston, J Langley, S Ahn, CJ Barnum, SA Factor, ...
Magnetic resonance imaging 32 (10), 1301-1306, 2014
1432014
High resolution imaging of the intracranial vessel wall at 3 and 7 T using 3D fast spin echo MRI
C Zhu, H Haraldsson, B Tian, K Meisel, N Ko, M Lawton, J Grinstead, ...
Magnetic Resonance Materials in Physics, Biology and Medicine 29, 559-570, 2016
782016
Occipital GABA levels in older adults and their relationship to visual perceptual suppression
K Pitchaimuthu, Q Wu, O Carter, BN Nguyen, S Ahn, GF Egan, ...
Scientific Reports 7 (1), 14231, 2017
632017
Bilateral neurostimulation systems used for deep brain stimulation: in vitro study of MRI-related heating at 1.5 T and implications for clinical imaging of the brain
R Bhidayasiri, JM Bronstein, S Sinha, SE Krahl, S Ahn, EJ Behnke, ...
Magnetic resonance imaging 23 (4), 549-555, 2005
602005
Effect of chronic unloading and rehabilitation on human Achilles tendon properties: a velocity-encoded phase-contrast MRI study
D Shin, T Finni, S Ahn, JA Hodgson, HD Lee, VR Edgerton, S Sinha
Journal of Applied Physiology 105 (4), 1179-1186, 2008
582008
Isotropic 3D black blood MRI of abdominal aortic aneurysm wall and intraluminal thrombus
C Zhu, H Haraldsson, F Faraji, C Owens, W Gasper, S Ahn, J Liu, G Laub, ...
Magnetic resonance imaging 34 (1), 18-25, 2016
532016
Fluid‐induced wall shear stress in anthropomorphic brain aneurysm models: MR phase‐contrast study at 3 T
S Ahn, D Shin, S Tateshima, K Tanishita, F Vinuela, S Sinha
Journal of Magnetic Resonance Imaging: An Official Journal of the …, 2007
512007
Multi-vendor standardized sequence for edited magnetic resonance spectroscopy
MG Saleh, D Rimbault, M Mikkelsen, G Oeltzschner, AM Wang, D Jiang, ...
Neuroimage 189, 425-431, 2019
472019
2D phase‐sensitive inversion recovery imaging to measure in vivo spinal cord gray and white matter areas in clinically feasible acquisition times
N Papinutto, R Schlaeger, V Panara, E Caverzasi, S Ahn, KJ Johnson, ...
Journal of Magnetic Resonance Imaging 42 (3), 698-708, 2015
472015
Accelerated whole brain intracranial vessel wall imaging using black blood fast spin echo with compressed sensing (CS-SPACE)
C Zhu, B Tian, L Chen, L Eisenmenger, E Raithel, C Forman, S Ahn, ...
Magnetic Resonance Materials in Physics, Biology and Medicine 31, 457-467, 2018
442018
Assessment of Reynolds stress components and turbulent pressure loss using 4D flow MRI with extended motion encoding
H Haraldsson, S Kefayati, S Ahn, P Dyverfeldt, J Lantz, M Karlsson, ...
Magnetic resonance in medicine 79 (4), 1962-1971, 2018
382018
Highly accelerated intracranial 4D flow MRI: evaluation of healthy volunteers and patients with intracranial aneurysms
J Liu, L Koskas, F Faraji, E Kao, Y Wang, H Haraldsson, S Kefayati, C Zhu, ...
Magnetic Resonance Materials in Physics, Biology and Medicine 31, 295-307, 2018
372018
Multisite reliability and repeatability of an advanced brain MRI protocol
DL Schwartz, I Tagge, K Powers, S Ahn, R Bakshi, PA Calabresi, ...
Journal of Magnetic Resonance Imaging 50 (3), 878-888, 2019
312019
In vivo estimation and repeatability of force–length relationship and stiffness of the human achilles tendon using phase contrast MRI
D Shin, T Finni, S Ahn, JA Hodgson, HD Lee, VR Edgerton, S Sinha
Journal of Magnetic Resonance Imaging: An Official Journal of the …, 2008
262008
The manifestation of vortical and secondary flow in the cerebral venous outflow tract: an in vivo MR velocimetry study
S Kefayati, M Amans, F Faraji, M Ballweber, E Kao, S Ahn, K Meisel, ...
Journal of biomechanics 50, 180-187, 2017
232017
Neuromelanin‐sensitive magnetic resonance imaging using DANTE pulse
S Oshima, Y Fushimi, T Okada, S Nakajima, Y Yokota, A Shima, ...
Movement Disorders 36 (4), 874-882, 2021
192021
Visualizing wall enhancement over time in unruptured intracranial aneurysms using 3D vessel wall imaging
B Tian, S Toossi, L Eisenmenger, F Faraji, MK Ballweber, SA Josephson, ...
Journal of Magnetic Resonance Imaging 50 (1), 193-200, 2019
172019
Correction for the T1 effect incorporating flip angle estimated by Kalman filter in cardiac‐gated functional MRI
J Shin, S Ahn, X Hu
Magnetic Resonance in Medicine 70 (6), 1626-1633, 2013
142013
Repeatability of proton magnetic resonance spectroscopy of the brain at 7 T: effect of scan time on semi-localized by adiabatic selective refocusing and short-echo time …
T Okada, H Kuribayashi, LG Kaiser, Y Urushibata, N Salibi, ...
Quantitative Imaging in Medicine and Surgery 11 (1), 9, 2021
122021
Ruptured intranidal aneurysm of an arteriovenous malformation diagnosed by delay alternating with nutation for tailored excitation (DANTE)–prepared contrast-enhanced magnetic …
K Komatsu, Y Takagi, A Ishii, T Kikuchi, Y Yamao, Y Fushimi, J Grinstead, ...
Acta Neurochirurgica 160, 2435-2438, 2018
92018
The system can't perform the operation now. Try again later.
Articles 1–20